PowMr 2000W Hybrid Solar Inverter Solar Battery DC 12V To AC 110V 2KVA Pure Sine Wave Inverter LED Display Work With Solar Panel


Price: [price_with_discount]$

PowMr 2000W Hybrid Solar Inverter Solar Battery DC 12V To AC 110V 2KVA Pure Sine Wave Inverter LED Display Work With Solar Panel POW-LVM2K-12V

Inverter Use Note:

The Battery Capacity OF The Correct Matching System Is Determined According To The Specific Usage Requirements OF The Load And Application Scenarios, Otherwise It will Easily Lead To Insufficient Battery Capacity Or Excessive Waste OF Power Generation.

Overviwe:

The PowMr Pure Sine Wave Power Inverter Charger delivers superior performance for remote off-grid applications.
The inverter is of pure sine wave capable of producing cleaner, smoother, and more reliable electricity for a user's electronic needs.
The power inverter is also able to charge the battery bank when AC power is connected to the inverter.

Featurs:

● Robust and sleek design
● LCD and LED display used to view inverter status and programming features
● Offers high-quality waveform with little harmonic distortion
● 4-Stage battery charger with a configurable charging current
● 8 Pre-Set battery voltages including Lithium; User-defined option available
● Automatic generator start option
● Peak efficiency >90%
● Multiple electronic protections

Pure Sine Wave:

The PowMr Power Inverters output a pure sine wave is similar to the waveform of the grid power. 
In a pure sine wave, the voltage rises and falls in a smooth fashion with very low harmonic distortion and cleaner utility-like power. 
This gives users stable enough power to operate tools, fans, lights, computers, and other electronics without any interference. 
pure sine wave inverters are in many cases more efficient, allowing users to use less energy and allow for more device capability. 
The main advantage of pure sine wave inverters is that they are used to operate sensitive electronic devices that require a high-quality waveform with little harmonic distortion. 
Almost any electronic device could be powered using a pure sine wave inverter.

Inverter Safety:

The inverters are suitable for 12V Battery Banks ONLY.
ALWAYS make sure the inverter is in the OFF position and disconnect all AC and DC connecting when working on any circuit associated with the inverter.
NEVER connect the AC output of the unit directly to an Electrical Breaker Panel/ Load Centre which is also fed from the utility power/generator.
When connecting battery terminals, ensure the polarity of the battery connections is correct. Incorrect polarity may cause permanent damage to the unit.
Be careful when touching bare terminals of capacitors as they may retain high lethal voltages even after power is removed.
The unit should be installed in a well-ventilated, cool, and dry environment. Make sure the fans of the unit and the ventilation holes are not blocked.
Do not expose the unit to rain, moisture, snow, or liquids of any type.

Package List:

  • 1 x 2000W Hybrid Inverter
  • 1 x Wired controller
  • 1 x user manual


Product Details:

MODEL
POW-LVM2K-12V
POW-HVM2K-12V
POW-LVM3K-12V
POW-HVM3K-12V
Rated Output Power
2000W
2000W
3000W
3000W
Transfer Time
10ms typical
Inverter mode
Nominal output voltage RMS
120/230VAC(100~120VAC 5V Gear setting;200~240VAC 10V Gear setting)
Output frequency
50HZ±0.3HZ or 60HZ±0.3HZ
Output waveform
Pure Sinewave
Output overload
105% < Load <120% ±10%: Fault(tum off output after 10 seconds)
120% < Load < 150% ±10%: Fault (turn off output after 3 seconds) 150%> Load ±10%: Fault (turn off output after 1 seconds)
Short circuit protection
Software protection
Nominal efficiency
>88%
Power factor
0.9-1
Line mode
Input voltage range
Narrow range
Wide range
Nominal output voltage±15%
Nominal output voltage +15%, -23%
Input frequency voltage
40Hz-70Hz
Input wave form
Sine wave(Utility or generator)
Short circuit protection
Circuit breaker
Output Overload
120%> Load <150%±10%: fault (turn off output after 60 seconds); 150%> Load ±10%: fault(tum off output after 1 seconds)
Over Charge protection shutdown
16.0 for 12V dc
Efficiency online transfer mode
>95%
AC Charge
Charge current can be set (5A UP/DOWN setting, For specific parameters, please refer to Appendix)
Selection of battery charging Voltage type
Battery type
Fast V
Float V
Gel U.S.A
14
13.7
A.G.M 1
14.1
13.4
A.G.M 2
14.6
13.7
Sealed Lead Acid
14.4
13.6
Gel Euro
14.4
13.8
Open Lead Acid
14.8
13.3
Calcium
15.1
13.6
Desulphation
15.5 for 4 hrs then off
Li
14.7
other
User-defined
Charge Current
65A
75A
Battery
Nominal DC Input Voltage
12V
12V
12V
12V
Battery voltage range
12V(10Vdc ~16Vdc) ±0.3Vdc
Low DC Warning Voltage
12V(10.5Vdc ± 0.3Vdc )
Low DC Cut-off Voltage
12V(10Vdc±0.3Vdc )
others
Operating Temperature Range
0-40℃
Humidity
0%~95%
Noise
<50dB
Dimension (D*W*H)mm
514*260*197
Related Products
Click
Click
Click
Click

Photo:

Other Articles You May Like To Read

Isuru Udana Hewapathirana

Isuru Udana Hewapathirana

As a BSc Electrical Engineer with over 7 years of experience in the solar industry, Isuru Hewapathirana is a seasoned professional in the field of solar energy. His expertise includes the design, installation, maintenance, and repair of photovoltaic (PV) systems, as well as the integration of renewable energy sources into existing electrical grids. With a focus on sustainability and efficiency, Isuru stays up-to-date on the latest technologies and industry standards, making him a reliable resource for both residential and commercial solar projects. Whether you are looking to reduce your carbon footprint with a small-scale solar panel installation or seeking a turnkey solution for a large-scale solar farm, Isuru has the skills and expertise to bring your vision to fruition.

Write Your Ideas and Suggestions to improve this post.

Leave a Reply

Your email address will not be published. Required fields are marked *