Price: [price_with_discount]$
![](https://ae01.alicdn.com/kf/Sef9ec93f64d941baa98e3229a88b968aq.jpg)
Soalr Inverter 1600W 6200W 3600W 8200W 10200W MPPT 500VDC PV Input 220VAC 24V 48VDC Pure Sine Wave hybrid inverter With WiFI
Feature:
10200W:Dual PV Input(Dual MPPT),Dual AC Output(Only 10200W models dual MPPT)
Model |
SCI-Max-8200 |
SCI-Max-10200 |
RATED POWER |
8200W
|
10200W |
Maximum PV Input Power |
8200W
|
10800W |
GRID-TIED OPERATION |
PV INPUT (DC) |
Nominal DC Voltage/Maximum DC Voltage |
360VDC/500VDC |
Start-up Voltage/Initial Feeding Voltage |
90VDC/120VDC |
MPPT DC Voltage Range |
90-450VDC |
Number of MPPT Trackers/Maximum
Input Current
|
1/27A
|
2/18A
|
GRID OUTPUT (AC) |
Nominal AC Output Voltage |
220/230/240VAC |
AC Output Voltage Range |
195.5-253VAC |
Power Factor |
>0.99 |
Feed-in Grid Frequency Range |
49-51±1Hz / 59-61±1Hz |
Nominal Output Current
|
35.6A
|
44.3A
|
EFFICIENCY |
Maximum Conversion Efficiency (Solar to AC) |
98% |
TWO LOADS OUTPUT POWER |
Full Load |
8200W
|
10200W |
Maximum Main Load |
8200W
|
10200W |
Maximum Second Load (battery mode)(Only if the battery voltage is below 44V) |
2733W
|
3400W |
Main Load Cut Off Voltage |
44VDC
|
44VDC |
Main Load Return Voltage |
48VDC
|
48VDC |
OFF-GRID OPERATION |
AC Start-up Voltage/Auto Restart Voltage
|
120-140VAC/180VAC
|
Acceptable Input Voltage Range
|
90-280VAC or 170-280VAC
|
Maximum AC Input Current
|
40A
|
50A
|
Nominal Operating Frequency
|
50/60Hz
|
Surge Power
|
16400W
|
20400W
|
BATTERY MODE OUTPUT (AC) |
Nominal Output Voltage |
220/230/240VAC |
Output Waveform |
Pure sine wave |
Efficiency (DC to AC) |
94% |
BATTERY & CHARGER |
Nominal DC Voltage |
48VDC
|
48VDC |
Maximum Charging Current(Solar to AC) |
160A
|
160A |
Maximum AC Charging Current |
140A
|
160A |
GENERAL |
Communication interface |
WIFI |
Humidity |
5% to 95% Relative Humidity (Non-condensing) |
Operating Temperature |
–10°C – 50°C |
Storage Temperature |
–15°C – 60°C |
![](https://ae01.alicdn.com/kf/S0b8816058d824afdb5a905d7f8682ec0t.jpg)
![](https://ae01.alicdn.com/kf/S1adf69da2ded4949bd35aee79086a4fbs.jpg)
![](https://ae01.alicdn.com/kf/S4349cdbce34a4ab6952ac4cd57a894fct.jpg)
![](https://ae01.alicdn.com/kf/S84993f393d1a4116b2829cdf7d3105538.jpg)
![](https://ae01.alicdn.com/kf/S6afe93d115e2433ab0baa22bf1626970U.jpg)
![](https://ae01.alicdn.com/kf/S8607a400b68b493a938eb815ee963a0eO.jpg)
![](https://ae01.alicdn.com/kf/Se7b20f9e6a614bd692ebf9d2b8d9dc9fN.jpg)
![](https://ae01.alicdn.com/kf/S42846c3c8e844dc587e5508b8123fce24.jpg)
![](https://ae01.alicdn.com/kf/Sd96fcdcdc541407c8a82d12c53ea706b7.jpg)
![](https://ae01.alicdn.com/kf/Sfb7ef3b2609f4f969852ac6d0d236929Q.jpg)
Model |
SCI-EVO-3600 |
SCI-ECO-4200 |
SCI-ECO-6200 |
RATED POWER |
3600W |
4200W |
6200W |
Maximum PV Input Power |
6200W |
6200W |
6500W |
GRID-TIED OPERATION |
PV INPUT (DC) |
Nominal DC Voltage/Maximum DC Voltage |
360VDC/500VDC |
Start-up Voltage/Initial Feeding Voltage |
90VDC/120VDC |
MPPT DC Voltage Range |
90-450VDC |
Number of MPPT Trackers/Maximum Input Current |
1/27A |
GRID OUTPUT (AC) |
Nominal AC Output Voltage |
220/230/240VAC |
AC Output Voltage Range |
195.5-253VAC |
Nominal AC Output Current |
15.7A |
15.7A |
27.0A |
Power Factor |
>0.99 |
Feed-in Grid Frequency Range |
49-51±1Hz / 59-61±1Hz |
EFFICIENCY |
Maximum Conversion Efficiency (Solar to AC) |
98% |
TWO LOADS OUTPUT POWER |
Full Load |
3600W |
4200W |
6200W |
Maximum Main Load |
3600W |
4200W |
6200W |
Maximum Second Load (battery mode) |
1200W |
1400W |
2067W |
Main Load Cut Off Voltage |
22VDC |
22VDC |
44VDC |
Main Load Return Voltage |
26VDC |
26VDC |
52VDC |
OFF-GRID OPERATION |
AC Start-up Voltage/Auto Restart Voltage |
120-140VAC/180VAC |
Acceptable AC Input Voltage Range |
90-280VAC or 170-280VAC |
Maximum AC Input Current |
30A |
40A |
Nominal Operating Frequency |
50/60Hz |
Surge Power |
7200W |
8400W |
12400W |
BATTERY MODE OUTPUT (AC) |
Nominal Output Voltage |
220/230/240VAC |
Output Waveform |
Pure sine wave |
Efficiency (DC to AC) |
94% |
BATTERY & CHARGER |
Nominal DC Voltage |
24VDC |
24VDC |
48VDC |
Maximum Charging Current(Solar to AC) |
120A |
Maximum AC Charging Current |
100A |
GENERAL |
Dimension, D x W x H (mm) |
420*350*110mm |
450*350*110mm |
Communication interface |
WIFI |
Humidity |
5% to 95% Relative Humidity (Non-condensing) |
Operating Temperature |
–10°C – 50°C |
Storage Temperature |
–15°C – 60°C |
![](https://ae01.alicdn.com/kf/S51420966fa0e4a86a6df54769c937545n.jpg)
![](https://ae01.alicdn.com/kf/S7e5e0afc11c84262973effbf5fe42c273.jpg)
![](https://ae01.alicdn.com/kf/S538fa4295be84ba58719490c4107f11aD.jpg)
![](https://ae01.alicdn.com/kf/Se35344fa192048eb95ed16cdb0fc68f8I.jpg)
![](https://ae01.alicdn.com/kf/Se090a03ab2e94329a220968b91a00bf1u.jpg)
![](https://ae01.alicdn.com/kf/S2a5f7722210446d389b1f4bd073af4dex.jpg)
![](https://ae01.alicdn.com/kf/S19898a056b394f918b920401dfe868517.png)
![](https://ae01.alicdn.com/kf/S95f9004b92514d4aa964d55c48de140f1.jpg)
FAQ:
Q:Whether it can directly supply power to the load?
A:YES
Q:Whether it can be connected to the grid?
A:PV gives priority to power supply to the load, and extra to charge the battery, and more can be integrated into the grid (need to be based on local government policies)
Q: Can inverters be connected in series or parallel?
A: NO.
Q: Is this a on grid-tied inverter? Can it be output to utility?
A: YES. It is a hybrid inverter that can be both off-grid and on-grid connected
Q: What types of batteries can be used?
A: Lead-acid batteries, gel batteries,Lithium Iron Phosphate(LiFePo4) and lithium batteries can be used. 24V battery for 3.6KW, 48V battery for 6.2KW. The battery cannot be less than 100AH.
Q: Can it be used in air conditioners, water pumps, and wind turbines?
A: It can be used in air conditioners, but not in water pumps and wind turbines.
Q: How to choose the power of the inverter according to the household appliances?
A: If household appliances contain inductive load appliances, such as refrigerators, washing machines, air conditioners, etc., the power of the inverter is at least three times the total power of the inductive load appliances, otherwise the appliances may not be able to start.
Q: Is it possible to use PV, battery, grid supply at the same time?
A: YES. The default PV priority mode, when the PV input is insufficient, the battery and utility will be used.
1. The starting power of inductive load electrical appliances shall be at least three times of the rated power of the electrical appliances. If the starting power exceeds the inverter power, the inverter may be damaged. Please select a suitable model before purchasing.
2. Please connect the circuit correctly according to the instructions, and install switches for each circuit.
3. Starting sequence: first turn on the battery switch, start the inverter, and turn on the PV, mains and load switches.
4. Shutdown sequence: turn off the switches of load, PV and mains, turn off the inverter, and finally turn off the battery.
About Us
Anern,has been dedicated in bringing clean energy to each country,and help people all around the world to enjoy the facility and convenience brought by clean energy.
12 years enperience in solar energy and led lighting industry.providing service to over 200 countries and areas globally.having developed over 3,000 solar energy projects worldwide.
Anern has successfully completed hundreds of mega government projects in the past 12 years
Anern is headquartered in guangzhou,which is one of the most important Chinese Central Cities.
In addition to headquarter in Guangzhou,Anern has also set up factories and offices in Shenzhen,Zhongshan and Zhejiang